EPA UCMR 5 Data · Mississippi

PFAS Drinking-Water Monitoring Results in Mississippi

This page summarizes EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5, 2023–2025) drinking-water monitoring records linked to ZIP codes in Mississippi, as processed for the PFAS Estimator national dataset. Data updated: July 2026.

5.1% of Mississippi ZIP codes in this dataset (217 total)
had at least one regulated PFAS compound detected at or above its applicable EPA threshold (11 of 217 ZIP codes). Of those, 4 (36.4%) had more than one compound at or above threshold. This dataset includes only ZIP codes with at least one recorded PFAS detection; ZIP codes where all compounds returned non-detect are not represented.

Compounds detected in Mississippi

Detection prevalence, exceedance, and concentration by compound, Mississippi ZIP codes in the EPA UCMR 5 analytic dataset.
Compound Applicable threshold ZIP codes detected At/above threshold Mean detected Maximum detected
PFOA0.004 µg/L (MCL)7 (3.2% of state)7 (100.0%) — all detections at/above limit by construction0.006 µg/L0.0087 µg/L
PFOS0.004 µg/L (MCL)8 (3.7% of state)8 (100.0%) — all detections at/above limit by construction0.0162 µg/L0.0722 µg/L
PFHxS0.01 µg/L (MCL)3 (1.4% of state)1 (33.3% of detected)0.0078 µg/L0.0136 µg/L
PFBS2.0 µg/L (HI reference)4 (1.8% of state)not calculated¹0.0062 µg/L0.0109 µg/L
Lithium7.36 µg/L (reference, not a regulatory limit)213 (98.2% of state)213 (100.0%) at/above reference26.0733 µg/L280.0 µg/L
PFPeA— (no federal limit)2 (0.9% of state)0.018 µg/L0.0245 µg/L
PFBA— (no federal limit)3 (1.4% of state)0.0079 µg/L0.01 µg/L
PFHpA— (no federal limit)2 (0.9% of state)0.0032 µg/L0.0034 µg/L
6:2 FTS— (no federal limit)2 (0.9% of state)0.0192 µg/L0.0229 µg/L

ZIP codes in this dataset (Mississippi)

217 ZIP codes with at least one recorded PFAS detection. Click a ZIP code to view its full compound-level results.

Per-ZIP-code detection summary for Mississippi
ZIP code Compounds detected At/above threshold
386061No
386101No
386141No
386291No
386353Yes (2)
386371No
386521No
386558Yes (3)
386631No
386661No
386711No
386777Yes (2)
386801No
386831No
387011No
387021No
387031No
387041No
387231No
387311No
387321No
387401No
387441No
387451No
387481No
387511No
387561No
387591No
387731No
387801No
388011No
388261No
388281No
388291No
388331No
388345Yes (2)
388351No
388411No
388431No
388461No
388471No
388491No
388501No
388571No
388581No
388601No
388631No
388641No
388651No
388661No
388681No
388711No
388761No
389011No
389021No
389161No
389201No
389211No
389221No
389271No
389301No
389351No
389481No
389521No
389531No
389541No
389611No
390381No
390411No
390421No
390461No
390471No
390561No
390571No
390591No
390601No
390661No
390691No
390711No
390731No
390741No
390831No
390901No
390971No
391101No
391112Yes (1)
391131No
391142Yes (1)
391151No
391161No
391171No
391191No
391202No
391301No
391441No
391451No
391501No
391541No
391561No
391571No
391591No
391661No
391681No
391701No
391751No
391801No
391811No
391821No
391831No
391891No
391901No
391911No
391931No
392081No
392091No
392161No
392181No
392321No
393011No
393021No
393031No
393041No
393051No
393071No
393091No
393201No
393251No
393261No
393271No
393281No
393321No
393351No
393371No
393381No
393391No
393411No
393421No
393451No
393471No
393501No
393551No
393591No
393601No
393641No
393651No
393661No
393671No
394012Yes (1)
394021No
394031No
394041No
394061No
394221No
394261No
394281No
394291No
394371No
394391No
394401No
394431No
394551No
394571No
394591No
394641No
394651Yes (1)
394661No
394701No
394751No
394762Yes (1)
394791No
394801No
394811No
395011No
395031No
395071No
395201No
395251No
395291No
395301No
395311No
395322Yes (1)
395331No
395342Yes (1)
395531No
395561No
395601No
395621No
395641No
395651No
395671No
395711No
395731No
395741No
395761No
395771No
395811No
396012No
396451No
396481No
396491No
396521No
396531No
396571No
396621No
396661No
396681No
397031No
397101No
397301No
397371No
397441No
397521No
397561No
397591No
397621No
397711No
397731No

Methodology & limitations

Results are based on EPA UCMR 5 monitoring data (2023–2025), linked to ZIP codes via Public Water System Identifier. Non-detections are not present in this analytic dataset. For each compound and ZIP code, the highest observed concentration across the monitoring period is retained; this characterizes the upper bound of observed drinking-water concentrations, not a long-term average or an individual exposure estimate. A single water system may serve multiple ZIP codes, so the same monitoring record can appear for more than one ZIP in this table. ZIP-code assignment reflects water-system service area geography and does not establish individual household exposure. Private wells are not represented unless served by a monitored public water system. PFOA and PFOS are reported by detection prevalence because the UCMR 5 reporting limit equals their federal MCL. A full PFBS Hazard Index is not calculated because co-located, same-event multi-compound readings are not retained in this dataset. Lithium has no federal Maximum Contaminant Level; 7.36 µg/L is an evidence-based reference concentration from a prospective cohort study, not a regulatory threshold.

Related links

PFAS Estimator homepage & national ZIP lookup
Full national methodology, limitations, and dataset documentation
All states & territories index

Data from the EPA Unregulated Contaminant Monitoring Rule (UCMR 5), 2023–2025. Detection does not indicate a health risk. Not medical advice. Data updated: July 2026. · EPA Source