EPA UCMR 5 Data · South Carolina

PFAS Drinking-Water Monitoring Results in South Carolina

This page summarizes EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5, 2023–2025) drinking-water monitoring records linked to ZIP codes in South Carolina, as processed for the PFAS Estimator national dataset. Data updated: July 2026.

79.7% of South Carolina ZIP codes in this dataset (232 total)
had at least one regulated PFAS compound detected at or above its applicable EPA threshold (185 of 232 ZIP codes). Of those, 148 (80.0%) had more than one compound at or above threshold. This dataset includes only ZIP codes with at least one recorded PFAS detection; ZIP codes where all compounds returned non-detect are not represented.

Compounds detected in South Carolina

Detection prevalence, exceedance, and concentration by compound, South Carolina ZIP codes in the EPA UCMR 5 analytic dataset.
Compound Applicable threshold ZIP codes detected At/above threshold Mean detected Maximum detected
PFOA0.004 µg/L (MCL)161 (69.4% of state)161 (100.0%) — all detections at/above limit by construction0.0066 µg/L0.018 µg/L
PFOS0.004 µg/L (MCL)168 (72.4% of state)168 (100.0%) — all detections at/above limit by construction0.0084 µg/L0.0328 µg/L
PFHxS0.01 µg/L (MCL)25 (10.8% of state)1 (4.0% of detected)0.005 µg/L0.019 µg/L
HFPO-DA0.01 µg/L (MCL)79 (34.1% of state)33 (41.8% of detected)0.0347 µg/L0.14 µg/L
PFBS2.0 µg/L (HI reference)170 (73.3% of state)not calculated¹0.0053 µg/L0.0156 µg/L
Lithium7.36 µg/L (reference, not a regulatory limit)54 (23.3% of state)54 (100.0%) at/above reference22.0996 µg/L49.4 µg/L
PFPeA— (no federal limit)179 (77.2% of state)0.0078 µg/L0.0399 µg/L
PFBA— (no federal limit)59 (25.4% of state)0.0073 µg/L0.0097 µg/L
PFHpA— (no federal limit)79 (34.1% of state)0.0037 µg/L0.0065 µg/L

ZIP codes in this dataset (South Carolina)

232 ZIP codes with at least one recorded PFAS detection. Click a ZIP code to view its full compound-level results.

Per-ZIP-code detection summary for South Carolina
ZIP code Compounds detected At/above threshold
290031No
290065Yes (2)
290167Yes (2)
290183Yes (1)
290203Yes (2)
290303Yes (1)
290335Yes (2)
290366Yes (2)
290383Yes (1)
290393Yes (1)
290401No
290446Yes (2)
290456Yes (2)
290534Yes (3)
290541No
290553Yes (2)
290561No
290581No
290616Yes (2)
290636Yes (2)
290671No
290706Yes (2)
290726Yes (3)
290735Yes (3)
290754Yes (2)
290784Yes (2)
291073Yes (1)
291086Yes (3)
291133Yes (1)
291153Yes (1)
291163Yes (1)
291183Yes (1)
291234Yes (3)
291264Yes (2)
291275Yes (2)
291281No
291295Yes (2)
291305Yes (2)
291333Yes (1)
291386Yes (3)
291456Yes (3)
291501No
291523Yes (3)
291531No
291541No
291615Yes (2)
291665Yes (2)
291695Yes (2)
291705Yes (3)
291715Yes (2)
291725Yes (2)
291804Yes (2)
292016Yes (2)
292036Yes (2)
292046Yes (2)
292056Yes (2)
292066Yes (2)
292076Yes (2)
292096Yes (2)
292106Yes (2)
292126Yes (2)
292236Yes (2)
292296Yes (2)
293232Yes (2)
293258Yes (3)
293306Yes (2)
293328Yes (3)
293358Yes (3)
293407Yes (2)
293416Yes (2)
293426Yes (2)
293518Yes (3)
293558Yes (3)
293608Yes (3)
293693Yes (1)
293708Yes (3)
293743Yes (1)
293763Yes (1)
293795Yes (2)
293848Yes (3)
293883Yes (1)
294014Yes (2)
294034Yes (2)
294044Yes (2)
294054Yes (2)
294064Yes (2)
294074Yes (2)
294094Yes (2)
294104Yes (2)
294124Yes (2)
294144Yes (2)
294184Yes (2)
294204Yes (2)
294244Yes (2)
294254Yes (2)
294264Yes (2)
294295Yes (2)
294316Yes (2)
294346Yes (2)
294364Yes (2)
294396Yes (2)
294406Yes (2)
294426Yes (2)
294454Yes (2)
294494Yes (2)
294506Yes (2)
294517Yes (2)
294536Yes (2)
294555Yes (2)
294566Yes (2)
294574Yes (2)
294616Yes (2)
294645Yes (2)
294655Yes (2)
294665Yes (2)
294686Yes (2)
294694Yes (2)
294704Yes (2)
294797Yes (2)
294824Yes (2)
294838Yes (2)
294845Yes (2)
294858Yes (2)
294864Yes (2)
294874Yes (2)
294924Yes (2)
295015Yes (2)
295055Yes (2)
295065Yes (2)
295101No
295117Yes (2)
295181No
295191No
295203Yes (1)
295267Yes (2)
295277Yes (2)
295321No
295415Yes (2)
295431No
295447Yes (2)
295457Yes (2)
295461No
295541No
295551No
295561No
295601No
295641No
295651No
295687Yes (2)
295697Yes (2)
295711No
295725Yes (2)
295741No
295757Yes (2)
295767Yes (2)
295777Yes (2)
295797Yes (2)
295801No
295817Yes (2)
295826Yes (2)
295856Yes (2)
295887Yes (2)
295891No
295901No
295921No
296111No
296203Yes (1)
296211No
296231No
296243Yes (2)
296251No
296263Yes (2)
296273Yes (1)
296283Yes (1)
296311No
296341No
296383Yes (1)
296401No
296421No
296448Yes (3)
296458Yes (3)
296465Yes (3)
296485Yes (3)
296495Yes (3)
296535Yes (3)
296548Yes (3)
296553Yes (2)
296571No
296593Yes (2)
296665Yes (3)
296698Yes (3)
296701No
296731No
296808Yes (3)
296818Yes (3)
296843Yes (2)
296928Yes (3)
296955Yes (3)
296971No
297027Yes (2)
297063Yes (2)
297075Yes (1)
297081No
297143Yes (2)
297151No
297203Yes (1)
297293Yes (2)
297301No
297311No
297321No
297441No
297451No
298163Yes (1)
298214Yes (1)
298223Yes (1)
298244Yes (1)
298293Yes (1)
298354Yes (1)
298384Yes (1)
298404Yes (1)
298413Yes (1)
298423Yes (1)
298444Yes (1)
298454Yes (1)
298473Yes (1)
298484Yes (1)
298603Yes (1)
298613Yes (1)
299094Yes (2)
299205Yes (2)
299265Yes (2)
299285Yes (2)

Methodology & limitations

Results are based on EPA UCMR 5 monitoring data (2023–2025), linked to ZIP codes via Public Water System Identifier. Non-detections are not present in this analytic dataset. For each compound and ZIP code, the highest observed concentration across the monitoring period is retained; this characterizes the upper bound of observed drinking-water concentrations, not a long-term average or an individual exposure estimate. A single water system may serve multiple ZIP codes, so the same monitoring record can appear for more than one ZIP in this table. ZIP-code assignment reflects water-system service area geography and does not establish individual household exposure. Private wells are not represented unless served by a monitored public water system. PFOA and PFOS are reported by detection prevalence because the UCMR 5 reporting limit equals their federal MCL. A full PFBS Hazard Index is not calculated because co-located, same-event multi-compound readings are not retained in this dataset. Lithium has no federal Maximum Contaminant Level; 7.36 µg/L is an evidence-based reference concentration from a prospective cohort study, not a regulatory threshold.

Related links

PFAS Estimator homepage & national ZIP lookup
Full national methodology, limitations, and dataset documentation
All states & territories index

Data from the EPA Unregulated Contaminant Monitoring Rule (UCMR 5), 2023–2025. Detection does not indicate a health risk. Not medical advice. Data updated: July 2026. · EPA Source